HDG Turbotec 50/60kW Log Boiler

What is special about HDG Turobotec 50/60kW

Turbotec right view
Photo of Turbotec right view
Turbotec left view
Photo of Turbotec left view
Turbotec front loading
Photo of Turbotec front loading
Turbotec top loading option
Photo of Turbotec top loading option
Primary and secondry air control motors
Photo of Primary and secondry air control motors

Fuel

  • Split log wood up to 1 metre lengths (39")
  • Pressed wood briquettes
  • Coarse cuttings and lumped wood waste, wood chips

Area of application

  • Private households
  • Agriculture and forestry
  • Commercial businesses

Properties

  • Front-loading
  • 340 litre fuel chamber volume
  • HDG Lambda-Control
  • Integrated ash box
  • Down-burning combustion technology

Benefits

  • Very user-friendly and convenient
  • Very long intervals between refills
  • Low emissions

Special features

  • 90% efficiency
  • Automatic cleaning of heat exchanger surfaces upon operation of the bypass damper
  • Operated entirely from the front
  • Meets the missions controls and safety requirements of most European countries
  • Awarded the German KWF prize for innovation
Turbotec cutaway diagram

Combustion-controlled, bottom-burning wood boiler

Type-tested to DIN EN 303-5 and DIN 4751-2, certified to EC Pressure Equipment Directive 97/23/EC. Pressure-tested, welded furnace body made of 5-6 mm tested boiler steel, fully lined filling chute (with heat-resistant special steel panels at particularly exposed points), sheet steel furnace lining, pre-assembled, powder-coated in green (RAL 6011) or yellow (RAL 1007) 80 mm glass wool insulation, safety heat exchanger fitted as standard.

CO2 Neutral Lambda Control 1 logo Photo of Lambda 1 face panel

Large fueling chamber

(340 liter, 1100 mm deep) for logs up to 1 meter and coarsely chopped wood for long refill intervals; highly temperature-resistant burn-off nozzle with special downstream combustion chamber for minimum emissions and maximum efficiency; power-controlled suction draught ventilator with servo drive for separate primary and secondary air control; oxygen and flue temperature sensors fitted ready to plug in; ergonomic design for convenient fueling using the large front door.

HDG Lambda Control 1 boiler control units

The boiler control units of HDG Lambda Control have ingenious combustion control systems. The combustion values are determined through the oxygen sensor and the flue gas sensor. These values are evaluated and the primary and secondary air flaps then precisely regulated for continuously optimal values even under variable conditions.

Technical Information
System type HDG Turbotec 50/60kW
Nominal thermal output 50/60kW
Fueling chamber volume 340 Litres
Fueling chamber depth 1100mm
Fueling chamber width 540mm
Maximum boiler temperature 95 deg C
Max. operating pressure 3 bar
Required flue draught 20 pa (0.08" wg)
Water content 370 Litres
Weight 940kg
Electrical connection 230AC, 50Hz
Flue connection size 180 mm (7")

HDG Lamdba Control 1

Intelligent emission management

In the HDG Lambda-Control 1, the following parameters are continually measured and also shown on the display:

The residual oxygen in the flue gas (with the aid of the oxygen probe), in order to achieve optimal combustion.

The exhaust air temperature (with the aid of the flue gas temperature sensor), in order to achieve a constant degree of efficiency;

The temperatures of the boiler and acumulator storage tank, in order to determine their operating statuses.