Lambda Control 1
High-tech for optimal values
HDG control systems employ the most modern electronics in order to achieve the lowest emissions, high performance and an impressive operating efficiency for the entire heating system.
Intelligent emission management
In the HDG Lambda-Control 1, the following parameters are continually measured and also shown on the display:
Functions
- Return flow temperature
- Maintenance
- Suction fan control
- Storage tank bypass
- Protection program
- Use of residual heat
- Refill signal and oil/gas boiler release
- Combustion control through oxygen probe as well as primary and secondary air control
- The residual oxygen in the flue gas (with the aid of the oxygen probe), in order to achieve optimal combustion.
- The exhaust air temperature (with the aid of the flue gas temperature sensor), in order to achieve a constant degree of efficiency; the temperatures of the boiler and accumulator storage tank, in order to determine their operating statuses.
The HDG Lambda-Control 1 continuously adapts the measured values automatically to the preset optimal values. Even with varying types of fuel, a constant burning quality is achieved.
Use of residual heat
The use of residual heat enables an optimal utilization of fuel and thereby results in longer intervals between refueling.
HDG Lambda-Control
The use of modern electronics makes it possible to continually improve the performance of wood heating systems. HDG puts this technology to use. HDG Lambda Control offers the following benefits:
- Very high degree of system efficiency.
- Especially low fuel consumption.
- Extremely low emission values.
This technology is intended for systems which need to be able provide absolute peak performance in the above mentioned areas.
Intelligent energy management
- Return flow temperature maintenance
- Integrated return flow temperature maintenance prevents corrosion damage
- Storage tank bypass. The storage tank bypass makes it possible to give priority to central heating and hot water. Residual heat utilization.
The use of residual heat enables the optimal utilization of fuel and significantly extends refill intervals.
Intelligent emissions management
The HDG Lambda Control system continuously monitors the following parameters and shows them on the display:
- Residual oxygen level in the flue gas (with the aid of the oxygen sensor)
- The exhaust temperature, for a constant degree of efficiency
- The temperature of the boiler and the storage tank
- The HDG Lambda Control system constantly adapts the measured values automatically to the preset optimal values. This enables optimal combustion quality to be maintained, regardless of the type, size and moisture content of the fuel being used
Protection program
Once every week - even in summer mode - the controller starts the protection program. This prevents corrosion of the boiler and the chimney by means of forced ventilation.
The oxygen sensor is automatically purged with oxygen and heated. In addition, the boilers motors start up, mixer valves operate and the water circulating pump is started and stopped to prevent "sticking".
Simple operation
Refilling and cleaning
As the boiler is refueled with fuel and cleaned, the fueling chamber is pre-ventilated and flue gases are evacuated by means of suction fans.
Quick engineer combustion test
An engineer can test for measuring nominal or partial loads and a safety test have been integrated as well.